climateprediction.net home page
Task 12504858

Task 12504858

Name famous_v4pr_1399_200_006732685_1
Workunit 6936026
Created 19 Jan 2011, 6:50:42 UTC
Sent 21 Jan 2011, 18:31:25 UTC
Report deadline 23 Apr 2011, 1:58:36 UTC
Received 28 Jan 2011, 10:11:31 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1120361
Run time 5 hours 7 min 33 sec
CPU time 4 hours 51 min 57 sec
Validate state Invalid
Credit 154.49
Device peak FLOPS 2.64 GFLOPS
Application version UK Met Office FAMOUS v6.11
windows_intelx86
Stderr
<core_client_version>6.10.58</core_client_version>
<![CDATA[
<message>
The device does not recognize the command. (0x16) - exit code 22 (0x16)
</message>
<stderr_txt>
Signal 11 received, exiting...
04:10:07 (4204): called boinc_finish
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=3508, iMonCtr=1
Model crash detected, will try to restart...

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  

Model crashed: ATM_DYN : INVALID THETA DETECTED.                                                                                                                                                                                                                               tmp/pipe_dummy                                                                  
Signal 11 received, exiting...
04:10:17 (4768): called boinc_finish
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=3508, iMonCtr=1
Model crash detected, will try to restart...

Model crashed: SUBROUTINE POTTEM STOPPING - PRESSURE OUT OF RANGE
Sorry, too many model crashes! :-(
04:10:24 (3508): called boinc_finish

</stderr_txt>
]]>
Latest Trickles Received
Time Sent (UTC) Host ID Result ID Result Name Timestep CPU Time (sec) Average (sec/TS)
28 Jan 2011 10:13:34 1120361 12504858 famous_v4pr_1399_200_006732685_1 46,826 14,999 0.3203
28 Jan 2011 10:13:34 1120361 12504858 famous_v4pr_1399_200_006732685_1 37,466 12,001 0.3203
28 Jan 2011 10:13:34 1120361 12504858 famous_v4pr_1399_200_006732685_1 28,106 9,002 0.3203
28 Jan 2011 10:13:34 1120361 12504858 famous_v4pr_1399_200_006732685_1 18,746 5,997 0.3199
28 Jan 2011 10:13:34 1120361 12504858 famous_v4pr_1399_200_006732685_1 9,386 3,012 0.3209


©2024 cpdn.org