Name | hadam3p_eu_wg9q_1974_1_007214926_2 |
Workunit | 7413206 |
Created | 11 Apr 2011, 0:49:41 UTC |
Sent | 11 Apr 2011, 1:10:28 UTC |
Report deadline | 23 Mar 2012, 6:30:28 UTC |
Received | 11 Apr 2011, 1:15:11 UTC |
Server state | Over |
Outcome | Didn't need |
Client state | Compute error |
Exit status | 0 (0x00000000) |
Computer ID | 1003607 |
Run time | 29 sec |
CPU time | 1 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 3.40 GFLOPS |
Application version | UK Met Office HadAM3P-HadRM3P Europe v6.09 windows_intelx86 |
Stderr | <core_client_version>6.10.58</core_client_version> <![CDATA[ <stderr_txt> Signal 11 received, exiting... Called boinc_finish Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=2080, selfPID=240, iMonCtr=1 Model crash detected, will try to restart... Regional Worker:: CPDN process is not running, exiting, bRetVal = 1, checkPID=2080, selfPID=2080, iMonCtr=2 Leaving CPDN_Main::Monitor... Called boinc_finish </stderr_txt> <message> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_1.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_2.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_3.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_4.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_5.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_6.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_7.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_8.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_9.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_10.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_11.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_12.zip</file_name> <error_code>-161</error_code> </file_xfer_error> <file_xfer_error> <file_name>hadam3p_eu_wg9q_1974_1_007214926_2_13.zip</file_name> <error_code>-161</error_code> </file_xfer_error> </message> ]]> |
No trickles! |
---|
©2024 cpdn.org