Name | hadcm3n_o6uu_2020_40_007856760_1 |
Workunit | 8011872 |
Created | 4 Apr 2012, 18:53:07 UTC |
Sent | 4 Apr 2012, 18:54:53 UTC |
Report deadline | 5 Jul 2012, 2:22:04 UTC |
Received | 27 Apr 2012, 2:42:41 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 193 (0x000000C1) EXIT_SIGNAL |
Computer ID | 1205756 |
Run time | 2 days 1 hours 38 min 50 sec |
CPU time | 1 days 21 hours 36 min 32 sec |
Validate state | Invalid |
Credit | 3,110.40 |
Device peak FLOPS | 4.50 GFLOPS |
Application version | UK Met Office Coupled Model Full Resolution Ocean v6.07 windows_intelx86 |
Stderr | <core_client_version>6.12.34</core_client_version> <![CDATA[ <message> - exit code 193 (0xc1) </message> <stderr_txt> CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... CPDN Monitor - Quit request from BOINC... CPDN Monitor - Quit request from BOINC... Suspended CPDN Monitor - Suspend request from BOINC... CPDN Monitor - Quit request from BOINC... Unhandled Exception Detected... - Unhandled Exception Record - Reason: Access Violation (0xc0000005) at address 0x77763AB3 read attempt to address 0x40B258D8 Engaging BOINC Windows Runtime Debugger... No Process Handle Worker:: CPDN process is not running, exiting, bRetVal = 1, checkPID=5056, selfPID=5056, iMonCtr=1 Unhandled Exception Detected... - Unhandled Exception Record - Reason: Access Violation (0xc0000005) at address 0x77E33AB3 read attempt to address 0x40B258D8 Engaging BOINC Windows Runtime Debugger... Cannot serialize file E:\program files\BOINCdata/projects/climateprediction.net/hadcm3n_o6uu_2020_40_007856760/dataout/shmem_restart.day Signal 11 received, exiting... Called boinc_finish </stderr_txt> ]]> |
Latest Trickles Received | ||||||
---|---|---|---|---|---|---|
Time Sent (UTC) | Host ID | Result ID | Result Name | Timestep | CPU Time (sec) | Average (sec/TS) |
26 Apr 2012 22:02:25 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 259,200 | 161,690 | 0.6238 |
25 Apr 2012 20:09:21 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 233,280 | 145,623 | 0.6242 |
25 Apr 2012 06:04:14 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 207,360 | 129,247 | 0.6233 |
24 Apr 2012 03:55:01 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 181,440 | 112,964 | 0.6226 |
20 Apr 2012 04:07:00 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 155,520 | 96,503 | 0.6205 |
17 Apr 2012 18:18:43 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 129,600 | 80,955 | 0.6247 |
17 Apr 2012 00:59:55 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 103,680 | 64,680 | 0.6238 |
15 Apr 2012 04:40:00 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 77,760 | 48,539 | 0.6242 |
13 Apr 2012 22:34:59 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 51,840 | 32,064 | 0.6185 |
12 Apr 2012 19:52:47 | 1205756 | 14358701 | hadcm3n_o6uu_2020_40_007856760_1 | 25,920 | 16,178 | 0.6242 |
©2024 cpdn.org