climateprediction.net home page
Task 21365954

Task 21365954

Name hadcm3s_st405_190012_120_771_011666910_0
Workunit 11666910
Created 5 Nov 2018, 22:11:59 UTC
Sent 6 Nov 2018, 7:39:43 UTC
Report deadline 19 Oct 2019, 12:59:43 UTC
Received 13 Dec 2018, 13:03:13 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1178743
Run time 4 days 20 hours 11 min 59 sec
CPU time 4 days 2 hours 58 min
Validate state Invalid
Credit 3,111.26
Device peak FLOPS 3.30 GFLOPS
Application version UK Met Office HadCM3 short v8.34
windows_intelx86
Peak working set size 403.23 MB
Peak swap size 641.79 MB
Peak disk usage 107.41 MB
Stderr
<core_client_version>7.6.22</core_client_version>
<![CDATA[
<message>
El dispositivo no reconoce el comando.
 (0x16) - exit code 22 (0x16)
</message>
<stderr_txt>
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=372, iMonCtr=1
Model crash detected, will try to restart...
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=3360, iMonCtr=1
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=5768, iMonCtr=1
Model crash detected, will try to restart...
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=4936, iMonCtr=1
CCController:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=4712, iMonCtr=1
Model crash detected, will try to restart...

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    

Model crashed: P_TH_ADJ : NEGATIVE PRESSURE VALUE CREATED.                                                                                                                                                                                                                     tmp/pipe_dummy                                                                  2048    
Sorry, too many model crashes! :-(
13:00:38 (5180): called boinc_finish(22)

</stderr_txt>
]]>