Name | hadam4_a0qj_209310_6_856_011962670_0 |
Workunit | 11962670 |
Created | 9 Dec 2019, 1:53:17 UTC |
Sent | 16 Dec 2019, 16:09:02 UTC |
Report deadline | 27 Nov 2020, 21:29:02 UTC |
Received | 17 Dec 2019, 1:44:18 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1495132 |
Run time | 37 min 50 sec |
CPU time | 34 min 15 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 2.17 GFLOPS |
Application version | UK Met Office HadAM4 at N144 resolution v8.09 i686-pc-linux-gnu |
Peak working set size | 618.66 MB |
Peak swap size | 647.00 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.8.3</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 19:44:02 (22138): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 climateprediction.net