Name | hadam4_a1xn_201310_6_914_012100072_0 |
Workunit | 12100072 |
Created | 8 Jul 2021, 10:30:01 UTC |
Sent | 29 Aug 2021, 11:04:20 UTC |
Report deadline | 11 Aug 2022, 16:24:20 UTC |
Received | 6 Sep 2021, 3:04:32 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1521339 |
Run time | 1 hours 9 min 44 sec |
CPU time | 1 hours 8 min 31 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 6.32 GFLOPS |
Application version | UK Met Office HadAM4 at N144 resolution v8.09 i686-pc-linux-gnu |
Peak working set size | 641.20 MB |
Peak swap size | 671.39 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.16.6</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 20:02:51 (541608): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 climateprediction.net