climateprediction.net home page
Task 22215707

Task 22215707

Name hadam4h_a0xm_200011_5_931_012139772_1
Workunit 12139772
Created 21 Jun 2022, 4:39:28 UTC
Sent 21 Jun 2022, 4:50:05 UTC
Report deadline 3 Jun 2023, 10:10:05 UTC
Received 21 Jun 2022, 5:50:45 UTC
Server state Over
Outcome Computation error
Client state Compute error
Exit status 22 (0x00000016) Unknown error code
Computer ID 1473345
Run time 1 min 25 sec
CPU time
Validate state Invalid
Credit 0.00
Device peak FLOPS 5.19 GFLOPS
Application version UK Met Office HadAM4 at N216 resolution v8.52
i686-pc-linux-gnu
Peak working set size 17.97 MB
Peak swap size 25.46 MB
Peak disk usage 0.02 MB
Stderr
<core_client_version>7.18.1</core_client_version>
<![CDATA[
<message>
process exited with code 22 (0x16, -234)</message>
<stderr_txt>
Could not read directory attributes: Value too large for defined data type
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01002207.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003255.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01005223.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003277.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01005207.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003236.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01010206.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003278.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01001218.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01005222.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003237.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003276.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003281.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003286.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003275.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003280.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003279.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003254.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01003274.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/stasets
                 File exists
                 unable to process datain/ancil/ctldata/stasets/X01005208.
Could not read directory attributes: Value too large for defined data type
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster
                 File exists
                 unable to process datain/ancil/ctldata/STASHmaster/STASHmaster_A.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster
                 File exists
                 unable to process datain/ancil/ctldata/STASHmaster/STASHmaster_O.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster
                 File exists
                 unable to process datain/ancil/ctldata/STASHmaster/STASHmaster_S.
checkdir error:  cannot create hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster
                 File exists
                 unable to process datain/ancil/ctldata/STASHmaster/STASHmaster_W.
Could not read directory attributes: Value too large for defined data type
Suspended CPDN Monitor - Suspend request from BOINC...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
Suspended CPDN Monitor - Suspend request from BOINC...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
Suspended CPDN Monitor - Suspend request from BOINC...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
Suspended CPDN Monitor - Suspend request from BOINC...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
forrtl: severe (24): end-of-file during read, unit 22, file /backup/boinc-client/projects/climateprediction.net/hadam4h_a0xm_200011_5_931_012139772/datain/ancil/ctldata/STASHmaster/STASHmaster_A
Image              PC        Routine            Line        Source             
hadam4_um_8.52_i6  083F6605  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  08414E81  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081033D8  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  081E0EBB  Unknown               Unknown  Unknown
hadam4_um_8.52_i6  0836E63F  Unknown               Unknown  Unknown
Suspended CPDN Monitor - Suspend request from BOINC...
Controller:: CPDN process is not running, exiting, bRetVal = 1, checkPID=0, selfPID=909201, iMonCtr=1
Model crash detected, will try to restart...
Sorry, too many model crashes! :-(
07:55:59 (909201): called boinc_finish(22)

</stderr_txt>
]]>
No trickles!