Name | hadsm4_a083_201310_6_935_012147053_1 |
Workunit | 12147053 |
Created | 28 Jul 2022, 10:02:02 UTC |
Sent | 28 Jul 2022, 10:52:08 UTC |
Report deadline | 10 Jul 2023, 16:12:08 UTC |
Received | 28 Jul 2022, 12:15:56 UTC |
Server state | Over |
Outcome | Computation error |
Client state | Compute error |
Exit status | 22 (0x00000016) Unknown error code |
Computer ID | 1318882 |
Run time | 22 min 57 sec |
CPU time | 12 min 35 sec |
Validate state | Invalid |
Credit | 0.00 |
Device peak FLOPS | 5.51 GFLOPS |
Application version | UK Met Office HadSM4 at N144 resolution v8.02 i686-pc-linux-gnu |
Peak working set size | 652.32 MB |
Peak swap size | 788.01 MB |
Peak disk usage | 5.78 MB |
Stderr | <core_client_version>7.16.16</core_client_version> <![CDATA[ <message> process exited with code 22 (0x16, -234)</message> <stderr_txt> Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Suspended CPDN Monitor - Suspend request from BOINC... Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Model crashed: ATM_DYN : NEGATIVE THETA DETECTED. tmp/xnnuj.pipe_dummy Sorry, too many model crashes! :-( 13:15:45 (1128616): called boinc_finish(22) </stderr_txt> ]]> |
No trickles! |
---|
©2024 climateprediction.net